Wavetek 3ST Specifications Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 102
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
4-18
Use the Up and Down arrow soft keys to cursor to a channel. Use the
C/N, HUM, and MOD soft keys to select the desired Auto Test
measurements.
Note: C/N, Hum, and Modulation cannot be measured on a
scrambled channel or a sweep point. Hum and Modulation cannot be
measured on a Digital type carrier.
Use the All/None soft key to quickly select or deselect Auto Test
measurements. If a test is selected, the None soft key is displayed. If
no tests are selected for a particular channel, then the All soft key is
displayed.
Edit Limits
The Edit Limits function works in conjunction with the performance
of an Auto Test. As the Auto Test measurements are made, the
values are compared to the above limits. Use the Up and Down arrow
soft keys to select the limit to be edited. Use the numeric entry keys
or the UP and DOWN arrow keys to enter a value. Once the value
has been entered, press the ENTER key to update the display.
Page view 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 101 102

Comments to this Manuals

No comments